Category
New Design Nb
Package Size 22.00cm * 12.00cm * 13.00cm Package Gross Weight 0.900kg -Product application in heating metering -Pipe mat
Basic Info.
Model NO. | 223F |
Main Application | Water |
Size | DN10-50 |
Sensor | Tube/Flange |
Application | Energy Metering |
Type | Ultrasonic Flow Meter |
Measuring Media | Liquid |
Measuring Principle | Ultrasonic |
Measurement Object | Closed Pipeline |
Certification | ISO |
Transport Package | Carton |
Specification | DN15-40 |
Trademark | ZPMETER |
Origin | China |
HS Code | 9026100000 |
Packaging & Delivery
Package Size 22.00cm * 12.00cm * 13.00cm Package Gross Weight 0.900kgProduct Description
-Product application in heating metering-Pipe material: copper
-Ultrasonic metering, no mechanical wear and tear, with excellent reliability, stability
-Accuracy level: Class 2
-Range ratio: R50/R100
-Temperature range: (5~95)ºC
-Temperature range: (2~90)K
-Compliance with standards: GB/T 32224 / EN1434
-Communication interface diversity: MBUS, RS485, pulse
Diameter | Min.Flow | Nominal Flow | Max. Flow | Length |
qmin(m³/h) | qp(m³/h) | qmax(m³/h) | mm | |
DN15 | 0.012 | 0.6 | 1.2 | 110 |
0.015 | 1.5 | 3 | ||
0.03 | 1.5 | 3 | ||
DN20 | 0.025 | 2.5 | 5 | 130 |
0.05 | 2.5 | 5 | ||
DN25 | 0.035 | 3.5 | 7 | 160 |
0.07 | 3.5 | 7 | ||
DN32 | 0.12 | 6 | 12 | 180 |
DN40 | 0.2 | 10 | 20 | 200 |
Accuracy Class | Class 2 | |||
Connection | DN20-DN40 is thread connection | |||
Pressure Loss | ≤0.02MPa | |||
Max.Working Pressure | 1.6MPa | |||
Temperature Sensor | 1.5m standard two-wire PT1000 paired temperature sensor(Wire length adjustable) | |||
Data Storage | 18 months history data | |||
Power outage protection | After a power failure, the accumulated flow rate recorded before the power failure and the corresponding time can be saved, and the metering function will be automatically restored after the power is restored. | |||
Interface & Communication | Infrared,MBUS/RS-485,Pulse | |||
Power | Built-in Lithium Battery | |||
Protection Class | IP65/IP67 | |||
Environmental | Class A | |||
Temperature range | (4~95)ºC | |||
Temperature difference range | (2~90)K | |||
Installation Method | Water inlet or return (default water inlet) | |||
Installation | Horizontal or Vertical | |||
Durability | Life Period ≥ 6 years | |||
Display | 8-bit LCD display | |||
Anti-magnetic interference | Distribution by a magnetic field with an intensity of less than 100 kA/m, no effective to the metering and remote transmission characteristics of the heat meter |